Join Now

Menu

Zd10-100 Datasheet _best_

When no pressure is applied, the resistance is infinite (open circuit). Actuation:

When no force is applied to the sensor strip, the internal conductive materials are separated. The initial resistance reads incredibly high— above 10 Megohms (MΩ) . It essentially functions as an open circuit.

Monitoring pressure variations in medical or fitness equipment.

| Feature | ZD10-100 | Mean Well LRS-100-12 | |---------|----------|----------------------| | Efficiency | 87% | 88% | | Hold-up time | 16 ms | 10 ms | | Operating temp | -20°C to +70°C | -25°C to +70°C | | Ripple | 120 mV | 100 mV | | Price bracket | Mid-range | Budget | zd10-100 datasheet

When no force is applied, the sensor acts as an open circuit with extremely high resistance (>10MΩ).

| Parameter | Value | |-------------------------|-----------------------------| | Supply voltage | 3.3 V DC (typical) | | Operating temperature | −20 °C to +60 °C | | Storage temperature | −20 °C to +60 °C (not explicitly stated but implied by the operating range) | | Maximum over‑load | Do not exceed 500 g force |

: Intelligent breathing belts, smart shelves, and automated home systems. When no pressure is applied, the resistance is

Pressure-sensitive buttons that respond differently based on how hard they are pressed.

Internal sensor trips at ~85°C case temperature. The power supply shuts down and automatically restarts when cooled to 65°C.

The ZD10-100 offers several features that make it suitable for specialized sensing tasks: It essentially functions as an open circuit

The following technical parameters are based on the latest manufacturer data: Specification Value Pressure Range Response Point ≤ 20g (up to 50g in some versions) Response Time Recovery Time Durability > 1 million times Initial Resistance > 10MΩ (No load) Minimum Resistance Approx. 500Ω (at full load) Operating Voltage Typical DC 3.3V Working Temperature -20°C to 60°C Dimensions 100mm (L) x 10mm (W) x ≤ 0.25mm (T) 2. Mechanical & Design Features

A review of the standard ZD10-100 Datasheet PDF from Sensor + Test reveals specific mechanical and electrical boundaries required for safe circuit design: Specification Value Notes / Conditions 0 to 500 grams Ideal for light touch and compression Physical Dimensions 100 mm (Length) × 10 mm (Width) Length includes active and terminal zone Thickness ≤is less than or equal to 0.25 mm to 0.30 mm Low profile allows internal device layering Response Point (Threshold) ≤is less than or equal to 20g to 50g Minimum force required to trigger initial step change Initial Resistance Measured under completely un-loaded conditions Recommended Test Voltage 3.3V DC (Typical) Compatible with standard 3.3V/5V MCU domains Response Time High-speed tactile detection capability Recovery Time Time required to settle back to base state Operating Temperature -20°C to 60°C Robust environmental envelope Durability Lifecycle Long mechanical lifespan under nominal load EMI / ESD Sensitivity None / Insensitive Immune to ambient electromagnetic noise Key Structural & Operational Features 1. Nanomaterial Composition & Human-Skin Emulation

Trip point: 105% to 150% of rated output current. Mode: Hiccup (auto-recovery) or constant current limiting (varies by OEM). The hiccup mode is preferred for driving motors, as it prevents thermal runaway.